Vision Controls Cam SS Version 5.01 Manual de instrucciones Pagina 55

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 71
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 54
54 / 69
Copyright © 2012 TOSHIBA TELI CORPORATION, All rights reserved.
http://www.toshiba-teli.co.jp/index.htm
D4211908A
Setting
- Set Manual Gain
Set the following value to “Gain” register. Setting value is Float type. This setting value is valid only at
Manual Gain mode setting.
setting value Gain
Minimum (*) 0.00 [dB]
Maximum 18.00 [dB]
* initial factory setting
The formula of Gain value is as follows;
- Select Gain control mode
Set the following value to “GainAuto” register. Setting value is Enumeration type.
setting value Mode
Off (*) Manual Gain Control (MANUAL)
Continuous Auto Gain Control (AGC)
* initial factory setting
Note
About the details of AGC mode, refer to “ALCControl” of "Functions".
Notes on gain setting:
Setting the gain value too high increases noises. When you adjust the brightness of the image, I ask you to have final
image quality checked with your environment.